The Y4-73 boiler and kiln ventilator and induced draft fans are primarily suitable for thermal power plants, steam boiler ventilator and induced draft systems, as well as kiln, smoke, and heat exhaust systems. Unless otherwise specified, the G4-73 can also be used for mine ventilation and general ventilation.
Send email to us
Product Description

The Y4-73 boiler and kiln ventilator and induced draft fans are primarily suitable for thermal power plants, steam boiler ventilator and induced draft systems, as well as kiln, smoke, and heat exhaust systems. Unless otherwise specified, the G4-73 can also be used for mine ventilation and general ventilation. The ventilator transports air with a minimum temperature of 80°C; the induced draft fan transports flue gas with a maximum temperature of 250°C.

Y4-73 Technical Parameters:

Machine numberSpeed r/minFlow rate (m³/h)Total pressure PaPower kw
8D145016156-204221303-129871
20442-309931284-86815
9D145023003-320791651-158422
35052-441281511-110030
96015229-29219721-4817.5
10D145031554-440042041-195937
48083-605531867-135945
96020891-40037891-59411
73015886-30475515-3435.5
11D145041999-474272474-246355
145053142-805702437-164675
16027806-533431079-71918.5
73021144-29487623-5987.5
32220-40562570-41511
12D145054526-689922949-290590
76040-1046002829-1961110
96036100-692531285-85630
73027451-34734742-73111
38282-52661712-49515
14D145086586-1095504029-3968185
120740-1661003864-2676220
96057326-725341752-172555
79944-1099701681-116775
73049225-435911010-100622
55156-83624995-67430
16D96085571-1082702293-2258110
119330-1641502200-1526132
73065069-734801321-131645
82333-1248201302-88055
58051699-99178833-55545
18D960121830-1699102908-2790200
185650-2337302659-1934220
73092684-1292001674-160690
141170-177301532-1115110
58073610-1026501055-101245
112160-141210965-70355